Description
Three cooling media for use during the cold drawing of steel wire were evaluated: air, oil, and water. Heat flow from the wire through the block to the cooling media was determined. Equipment, calculations, and results are discussed.
$15.00
Three cooling media for use during the cold drawing of steel wire were evaluated: air, oil, and water. Heat flow from the wire through the block to the cooling media was determined. Equipment, calculations, and results are discussed.
Three cooling media for use during the cold drawing of steel wire were evaluated: air, oil, and water. Heat flow from the wire through the block to the cooling media was determined. Equipment, calculations, and results are discussed.
Author(s) | Wilson, N.A., Morgan Construction Co., Holbrook, J.A. |
---|---|
Publication/Event/Pages | Wire & Wire Products41(12): 2002-2005, 2064-2065 1966, Paper presented at WAI 36th Annual Convention, Pittsburgh, PA USA |
Year | 1966 |