An investigation of a lime coating failure

$15.00

Investigations carried out to determine the cause of a series of failures of lime coatings on metal plates are described. It was determined that when making up lime tubs, cold water rather than hot should be used in order to insure the proper concentration of Ca(OH) 62 1.

SKU: P00772 Category: Tags: ,

Description

Investigations carried out to determine the cause of a series of failures of lime coatings on metal plates are described. It was determined that when making up lime tubs, cold water rather than hot should be used in order to insure the proper concentration of Ca(OH) 62 1.

Additional information

Author(s)

Washburn, D.E., Warner Co.

Publication/Event/Pages

Wire & Wire Products16(9): 501-502, 528 1941

Year

1941