Description
This paper describes the effectiveness of segmental conductors with cupric oxide film applied on each strand for reduction of AC resistance. This new conductor was used for a 275kV 3 x 2500 mm2 pipe-type oil-filled cable with the route length of 3.4 km which was installed for the Chubu Electric Power Co. Ltd. Manufacturing methods are described.