Use of lubricants for corrosion protection on hard-drawn, high carbon wire

$15.00

A template of an experimental procedure developed to qualify lubricants for use as a rust-inhibiting layer on hard-drawn, high-carbon wire is given. The test cycle of 70 hours at 100F, and 96-98% relative humidity is described in three phases; corresion protection, consumption, and customer approval.

Description

A template of an experimental procedure developed to qualify lubricants for use as a rust-inhibiting layer on hard-drawn, high-carbon wire is given. The test cycle of 70 hours at 100F, and 96-98% relative humidity is described in three phases; corresion protection, consumption, and customer approval.

Additional information

Author(s)

Montague, S.M.Leggett & Platt, Inc.

Publication/Event/Pages

Wire Journal International17(12): 48-50 1984, Paper presented at WAI Nonferrous/Electrical Joint Meeting, Providence, RI USA

Year

1984