Analysis and automation of copper surface oxide measurement

$15.00

The usual commercial method used to measure thickness of surface oxide film on copper is based upon coulometric reduction principles. In this production test, inaccuracies and anomalies may result from higher current, oxygen in the electrolyte, oxides in cracks and residual lubricant. These influences are evaluated by comparison with ellipsometry analysis and will be discussed along with a method for automation.

Description

The usual commercial method used to measure thickness of surface oxide film on copper is based upon coulometric reduction principles. In this production test, inaccuracies and anomalies may result from higher current, oxygen in the electrolyte, oxides in cracks and residual lubricant. These influences are evaluated by comparison with ellipsometry analysis and will be discussed along with a method for automation.

Additional information

Author(s)

Gil Baker and Horace Pops, Essex Group, Inc., USA

Publication/Event/Pages

Paper presented at WAI 68th Annual Convention, Cleveland, OH USA. Paper published in Wire Journal International, Feb. 1999, pg. 90.

Year

1998