Description
A taxonomy has been developed for dielectric failures occuring in enamel coated copper magnet wires during application of high voltage alternating current. Defects have been identified using metallographic examination, elemental analysis and scanning electron microscopy, and can be broken down into six distinct major classifications contingent upon their origins. Comparisons between continuity faults and flaws associated with beady wire are discussed.